Specifications
102 209351 REV B Operations Manual, Redundant System Controllers
settingIndex/settingValue
settingTextValue Value OID Description
1/INTEGER SysMode'1:2=0,1:1=1,1:1Phasecombined=2;Dual 1:1 1.3.6.1.4.1.20712.2.1.1.1.2.1 System Operation mode
2/INTEGER SwitchMode'Auto=0,Manual=1 1.3.6.1.4.1.20712.2.1.1.1.2.2 System Switching Mode
3/INTEGER ControlMode'Local=0,Remote=1 1.3.6.1.4.1.20712.2.1.1.1.2.3 System Control Mode
4/INTEGER Reserved 1.3.6.1.4.1.20712.2.1.1.1.2.4 Field reserved for factory use
5/INTEGER Priority'Pol1=0,Pol2=1 1.3.6.1.4.1.20712.2.1.1.1.2.5 Switching priority
6/INTEGER Protocol'Normal=0,Terminal=1 1.3.6.1.4.1.20712.2.1.1.1.2.6 Remote serial control protocol
7/INTEGER Baud'9600=0,2400=1,4800=2,19200=3,38400=4 1.3.6.1.4.1.20712.2.1.1.1.2.7 Baud rate of serial interface
8/INTEGER NetworkAddress'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.8 Unique network address
9/INTEGER Interface'RS232=0,RS485=1,IPNet=2,SNMP=3 1.3.6.1.4.1.20712.2.1.1.1.2.9 Type of remote control interface
10/INTEGER FaultMonitor'SSPA=0,LNA/LNB=1,Both=2 1.3.6.1.4.1.20712.2.1.1.1.2.10 Type of fault monitoring
11/INTEGER AuxFaultMonitoring'On=0,Off=1 1.3.6.1.4.1.20712.2.1.1.1.2.11 Auxiliary fault monitoring
12/INTEGER RFSwitchFault'Major=0,Alert Only=1,Alternate=2 1.3.6.1.4.1.20712.2.1.1.1.2.12 RF switch fault monitoring
13/INTEGER FaultLatch'Enable=0,Disable=1 1.3.6.1.4.1.20712.2.1.1.1.2.13 Fault latch
14/INTEGER FaultWindow'20%=0,8%=1,12%=2,15%=3 1.3.6.1.4.1.20712.2.1.1.1.2.14 LNB/LNA current fault monitoring window
15/INTEGER FaultLogic'FaultOnLow=0,FaultOnHigh=1 1.3.6.1.4.1.20712.2.1.1.1.2.15 SSPA and Aux fault logic
16/INTEGER UserPassword'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.16 User menu password
17/INTEGER StandbyUnit'Default=0,Unit1=1,Unit2=2,Unit3/combine=3 1.3.6.1.4.1.20712.2.1.1.1.2.17 Unit standby select
18/INTEGER Buzzer'On=0,Off=1 1.3.6.1.4.1.20712.2.1.1.1.2.18 Audible alarm
19/INTEGER MenuPassword'On=0,Off=1 1.3.6.1.4.1.20712.2.1.1.1.2.19 Menu password state
20/INTEGER
SSPASubSystem'None=0,CO SSPA=1,RM SSPA=2,Reserved=3,
vBUC=4
1.3.6.1.4.1.20712.2.1.1.1.2.20 Type of optional SSPA subsystem
21/INTEGER RFPowerUnits'dBm=0,Watts=1 1.3.6.1.4.1.20712.2.1.1.1.2.21 Frwd/Reflected power measurement units
22/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.22 Field reserved for factory use
23/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.23 Field reserved for factory use
24/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.24 Field reserved for future use
25/INTEGER SubsystemMute'On=0,Off=1 1.3.6.1.4.1.20712.2.1.1.1.2.25 SSPA Subsystem mute control
26/INTEGER SubsystemAttenuation(dBx10)'0..200 1.3.6.1.4.1.20712.2.1.1.1.2.26 SSPA Subsystem attenuation control
27/INTEGER SwitchMute'Off=0,Internal=1,External=2,All On=3 1.3.6.1.4.1.20712.2.1.1.1.2.27 Switch muting state
28/INTEGER FaultTollerance'None=0,OneFault=1,TwoFaults=2 1.3.6.1.4.1.20712.2.1.1.1.2.28 Fault tolerance option
Table 7-11: Detailed Settings