The factory default for all Any-to-Any ports on all aggregation taps (SS-1200-S series and
SS-2200-S series) are turned off by default - i.e. they are not set up as either inputs or
outputs and are not replicated to any other ports with the exception of the hard-wired in-
line taps.
The default configuration has Ports 1 and 2 hard-wired as an inline tap. Ensure there are no previous
settings present, go through Ports 1-4 and set them to OFF as shown:
# SET PORT MONITOR 1 OFF
# SET PORT MONITOR 2 OFF
# SET PORT MONITOR 3 OFF
# SET PORT MONITOR 4 OFF
Now you can begin setting the Tap and Any-to-Any ports as to which port inputs the data and
which ports aggregate and/or output the data.
Port 3 is set as output for Port 1 and 2’s input which is set with this syntax:
# SET PORT MONITOR 3 FROM 1,2
Port 4 is set as output for Port 1 and 2’s input which is set with this syntax:
# SET PORT MONITOR 4 FROM 1,2
IMPORTANT: If desired, this BT tap could be configured to have traffic, for example TCP resets,
injected from Any-to-Any ports.