User guide
Initial Configuration 53
© 2012 Datacom Systems Inc
Port 7 is set as output for Port 1’s input/output which is set with this syntax:
# SET PORT MONITOR 7 FROM 1
Port 8 is set as output for Port 2’s input/output which is set with this syntax:
# SET PORT MONITOR 8 FROM 2
Port 9 is set as output for Ports 1 and 2’s input/output which is set with this syntax:
# SET PORT MONITOR 9 FROM 1,2
Port 10 is set as output for Ports 1, 2, 3, and 4’s input which is set with this syntax:
# SET PORT MONITOR 10 FROM 1,2,3, 4
As a quick check, show port routing interface matrix with this syntax:
# SH PO RO
Outputs
01 02 03 04 05 06 07 08 09 10
01 ------------X--------------------------------X-----------X-----X
02 ------X---------------------------------------------X----X-----X
03 ---------------------------------------X-------------------------X
04 ---------------------------------X----X-------------------------X
05 --------------------------------------------------------------------
06 --------------------------------------------------------------------
07 ------X------------------------------------------------------------
08 ------------X------------------------------------------------------
09 ------X----X------------------------------------------------------
10 --------------------------------------------------------------------
#
This completes the exercise using the Command Line Interface for setting ports.
4.6 Management Connection (RJ45)
Once installation of the Link Aggregation Tap has been completed in your chosen network location,
see Hardware Installation section, management connection is initiated over the network via either
TELNET or SSH as explained in the following section.
61