User guide
SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps52
© 2012 Datacom Systems Inc
The default configuration has Ports 1 and 2 hard-wired as an inline tap Ensure there are no previous
settings present, go through Ports 1-10 and set them to OFF as shown:
# SET PORT MONITOR 1 OFF
# SET PORT MONITOR 2 OFF
# SET PORT MONITOR 3 OFF
# SET PORT MONITOR 4 OFF
# SET PORT MONITOR 5 OFF
# SET PORT MONITOR 6 OFF
# SET PORT MONITOR 7 OFF
# SET PORT MONITOR 8 OFF
# SET PORT MONITOR 9 OFF
# SET PORT MONITOR 10 OFF
Now you can begin setting the Tap and Monitor ports as to which port inputs the data and which
ports aggregate and/or output the data.
Port 1 is set as output for Ports 7, 8 and 9’s input which is set with this syntax:
# SET PORT MONITOR 1 FROM 7,8,9
Port 2 is set as output for Ports 7, 8 and 9’s input which is set with this syntax:
# SET PORT MONITOR 2 FROM 7,8,9
Port 5 is set as output for Port 4’s input which is set with this syntax:
# SET PORT MONITOR 5 FROM 4
Port 6 is set as output for Ports 3 and 4’s input which is set with this syntax:
# SET PORT MONITOR 6 FROM 3,4