6 Installation location
Please select a torsion-free, stable mast with a minimum diameter of 60 mm. The location should
fulfil the following requirements in order to ensure the best possible measurement.
no bend
no uphill/downhill gradient
no moving objects (e.g. bushes) in the “line of vision” of the radar
no reflecting surfaces (e.g. glass front of buildings) within the field of vision of the radar
no large metal objects (e.g. crash barriers) within the field of vision of the radar
free “view” of the lane to be measured
The DSD must be aligned laterally in such a way that it is as parallel as possible to the road
surface.