Tasks and Kits
ProMaster 2500 User Manual 3-9
•
Label
—Select this parameter to label the devices. Devices do not
have to be programmed (or verified) and labeled in the same process.
They can be programmed and placed in tubes to be labeled by the
2500 later. The 2500 default configuration will not label devices that
have failed the programming operation. (The 2500 can be configured
to label both passed and failed devices. Refer to the
Binning
command in local mode in Appendix F.) Devices that have failed can
be labeled only by passing them through the 2500 a second time.
Selecting Handling/
Labeling Parameters
Numerous parameters are available by selecting the
< More >
pushbutton. Press
↵
and the
More Task Parameters
selection box
appears (see Figure 3-1, screen 4). Most of these should remain at their
default settings.
The parameters that must be defined for all Tasks are the
Handling/
Labeling Parameters...
selections. Move the screen cursor over
Handling/Labeling Parameters...
and press
↵
to select this parameter
set. The following handler and labeler parameters are defined in this
dialog box.
Selecting the Package Type
The
Package
field defines the device package type you will be
processing. Move the screen cursor to this field and press
F2
. TaskLink
displays a list of package and pin counts from 8-pin DIP to 84-pin PLCC
devices. The package type “
DIP 24-.3
” represents a 24-pin DIP device in a
300 mil. package width.
To select a new package type, move the screen cursor to the new type and
press
↵
.
Device Orientation: Pin 1
Press
T
AB
to move to the
Pin 1 Orientation
field. This parameter is
critical because it tells the 2500 where pin 1 on the device will be
positioned in the input track. The beam inserts the device into the
programming module with pin 1 always to the right, pointing toward the
input tube. The Task must accurately identify the position of pin 1 as the
devices are loaded in the input track so that the beam rotates and inserts
it in the programming module correctly.
Figure 3-6