Local Mode
F-10 ProMaster 2500 User Manual
Labeler Setup Menu
This menu allows you to alter parameters which affect the printing of
characters on a label and the application of that label on a device.
Label Calibration
Label calibration determines the distance between the edge of the label
and the first printed character. If characters are not being printed on the
label with the correct spacing from the label’s edge, make sure that the
following have been checked:
• Labels have been calibrated.
• Labeler’s pinch rollers are fully engaged against the drive roller.
• ADC value is correctly set to 200.
Note: When you are running a Task or performing any other handler operation,
it is best to use the Stop command
LOWER CASE
+
C
for this parameter.
To change the current label calibration value from the 2500’s front panel,
put the 2500 in local mode. Press
1
from the Labeler Setup menu.
The 2500 displays:
Use the 2500’s keyboard to change the setting. The range is from 0 to 255.
After entering the desired value, save it by pressing the ENTER key. The
2500 records this value as the new default and returns to the Labeler
Setup menu.
Note: If you change the label calibration value, press the CAL key so that the
ADC optic performs the ADC optic label calibration.
Label Placement
The label placement default setting centers the label on the device.
Change this setting from the 2500’s front panel by first putting the system
in local mode. From the Main Menu, press
3
.
From the Labeler Setup menu, press
2
to select LABEL PLACEMENT.
* * * LABELER SETUP MENU * * *
1 - LABEL CALIBRATION 4 - SETUP MENU
2 - LABEL PLACEMENT
3 - LABEL ADJUST
ENTER LABEL CALIBRATION VALUE (XX):_
* * PROMASTER 2500 MAIN MENU * *
ENTER THE NUMBER OF THE DESIRED FUNCTION
1 - OPERATIONS 3 - SYSTEM SETUP
2 - FILE UTILITIES 4 - DIAGNOSTICS
* * * LABELER SETUP MENU * * *
1 - LABEL CALIBRATION 4 - SETUP MENU
2 - LABEL PLACEMENT
3 - LABEL ADJUST