User manual

Computer Remote Control
E-10 ProMaster 2500 User Manual
Handler CRC Error
Codes
If the 2500 stops during operation due to an error, the audible alarm
sounds, and one of the following messages is displayed. The 2500 sends
an error code to the remote computer in the form of a
#
followed by a
three-digit decimal between E00 and E99, followed by a CR-LF. In most
cases, the operator must take some corrective action and press a key to
restart the 2500.
For example, #E07 indicates an
UNABLE TO LOWER BEAM
error. As soon
as the beam is lowered, the 2500 sends #000 to indicate the error
condition has been cleared and then resumes operation.
These error codes and their corresponding messages, which can occur
any time during the execution of a remote command, are listed below:
Code Error Text
000
ERROR CLEARED.
002
LABELS NOT CALIBRATED, PRESS START.
003
ENTER DOT SPLIT VALUE.
004
UNABLE TO PICK DEVICE, PRESS START.
005
OUT OF LABELS, PRESS START.
006
TESTSITE CLAMP MALFUNCTION, PRESS START.
007
UNABLE TO LOWER BEAM, PRESS START.
008
UNABLE TO RAISE BEAM.
009
BEAM MOTOR MALFUNCTION, PRESS KEY.
010
HANDLER PORT MALFUNCTION.
011
REMOTE COMPUTER NOT READY.
012
PROGRAMMER NOT READY.
013
INVALID PROGRAMMER RESPONSE, PRESS KEY.
014
PROGRAMMER NOT RESPONDING.
015
ERROR RECEIVED WHILE ATTEMPTING LOAD.
016
TARGET DEVICE COUNT ACHIEVED, PRESS KEY.
017
CHECKSUM ERROR.
018
INVALID DATA FORMAT.
019
DEVICE SIZE DATA RECORD IS MISSING.
020
DEVICE ROTATION DATA RECORD IS MISSING.
021
DEVICE ERROR CLEARED, PRESS START.
022
INPUT CAL ERROR, PRESS START.
023
OUTPUT CAL ERROR, PRESS START.
027
RECEIVING TUBE NOT AVAILABLE.
028
CATEGORY.
029
DEVICE JAM AT OUTPUT TUBE, PRESS START.
099
ILLEGAL REMOTE COMMAND.