ProMaster 2500 User Manual E-9
Response: R16 (when rotation is completed)
@@17
X
Define Pass Category
—
X
represents category number 1 to 5.
This command allows the remote computer to define the pass category. If
this command is not sent, the 2500 assumes that all parts receiving a label
are good. When a part is good, the “PART TOTAL” is incremented and
compared to the “PROGRAM TARGET” to determine if the run is
complete.
Response: R17
@@18 Handler Identification
—This command allows the remote computer to
determine the type of Data I/O handler.
Response: R2500
@@21 Print Only
—Causes the 2500 to print labels only. This is followed by a
hex file. The user must press
START
for each printed label. To invoke a
new command, send a ! (the reset command).
Response: R21
@@22 Purge
—Cycles devices remaining in the system to the output tubes.
Response: R22
@@23
X
Contact Adjust
—Determines whether the 2500 will stop with the first
device and ask the operator to align the device to the programming
module contacts.
X = 0 Do not stop for contact adjust
X = 1 Stop for contact adjust
Response: R23
# Request Number Of Devices Labeled
—This command returns the
number of devices labeled since the last @01 or @02 command. It may be
sent at any time.
Response: R
XXXX
(
XXXX
= four-digit decimal number in ASCII)
!Reset
—This command stops any command in progress and prepares the
2500 to accept the next command. A reset may be sent at any time.
WARNING:A 500 millisecond delay must occur before the next
command is issued.
Response: None
*
(asterisk)
Terminate job
—This command is used to terminate a job initiated by the
@03
XX
, @12
XXXX
, or @13
XXYYZZZZ
commands before the specified
part count has been reached.
After the * is received, the 2500 sets the current device in the appropriate
output track and does not pick the next device from the input track.
Response: R* after the last part is sorted