User manual

Introduction
ProMaster 2500 User Manual 3/97 1-17
The 2500’s keyboard and display will be used by the system
administrator and/or service technician when they want to:
Stop the handler during a job (Task), adjust a parameter, and then
continue running the Task from the same point. (A complete list of
the available
STOP
commands can be found in Appendix B.)
Run tests on the labeler using the
Print Only
mode.
•Operate in
Local
mode to run system diagnostics.
2500 Handler Specifications
Functional
Print Density
12 to 26 characters per inch (dot matrix labeler)
11 to 28 characters per inch (thermal labeler)
Control Interface
Three serial RS-232C ports (default: 9600 Baud)
Throughput
Up to 550 devices per hour
(actual throughput depends on programming/testing time for the
specific device and labeling requirements)
User RAM
8MB standard
Floppy Disk Format
Double-sided, quad-density 3.5” disk with 135 tracks/inch; 1.44MB
formatted
Mass Storage Module
Internal hard drive (user drives C and D; system drives H and I);
User drives formatted to 32MB, maximum number of files per drive
= 512.
Controller
Motorola 68000 16-bit microprocessor
Communication Standard
RS-232C
Data transfer rate
300 to 19.2K baud (data file transfer up to 115.2K baud using
TaskLink)
Programming Modules DIP:
8- to 28-pin in 0.3-inch package width
20- to 32-pin in 0.6-inch package width
PLCC:
20-, 28-, 32-, 44-, 52-, 68-, and 84-pin
Lead Pitch Width: 0.050 inch
SOIC:
Package Width
0.150 (150 to 220 mil)
0.300 (300 mil)
0.350 (0.330 to 0.350)
0.450 (0.420 to 0.450)
0.530
*
(0.500 to0.530)
* To use a 500-mil SOIC programming module, you must have the 88-pin version of the
ProMaster 2500.
Max. Pin Count
8 pins
32 pins
32 pins
40 pins
56 pins