User manual
Firmware Keys and STOP Commands
B-2 ProMaster 2500 User Manual
Function Keys to Press Description
While in Remote
Mode:
Local mode
LOWER CASE + L
Changes the 2500 from remote mode to local mode.
Select this mode to run operations such as
diagnostics tests and firmware keys.
While in Local Mode:
Remote mode
LOWER CASE + R
Changes the 2500 from local mode to remote mode.
Display intensity
↓ ↑
Adjust the intensity of the display.
From the Main Menu:
Advance label
LOWER CASE + A
Advances the label’s position for application on the
device. The nominal range is 35 to 60.
Restore factory default
parameters
LOWER CASE + D
Sets all handler parameters to their original software
default values. Use lower case “y” to activate this
function.
Remote mode
LOWER CASE + R
Puts the handler in computer remote control mode
(required for operation with TaskLink PC software).
Set time-out delay for
programming module
LOWER CASE + T
Sets a delay between the time a device is inserted into
the programming module and when TaskLink sends
the command to start programming. When you run
the Cycle Parts operation, this command defines the
length of time the device will be held in the
programming module, simulating a device’s being
programmed. Each digit on the display equals 100
milliseconds (default = 2).
Printer type
LOWER CASE + W
Configures the 2500 for thermal or dot matrix printer
operation.
From the File Utilities Menu:
Delete label files
LOWER CASE + A
Deletes all label files stored in the system. A warning
prompt is displayed.
From the Diagnostics/Optic Test Menu:
Adjust ADC Optic
LOWER CASE + A
Adjust the ADC value to 200 using the
↑
and
↓
.
Reset motor encoder
LOWER CASE + R
Resets the beam traverse motor’s encoder to zero.
Used for motor testing.
Vacuum generator
On/Off
V
Turns the vacuum generator on and off while you
run the Optics diagnostic test.
Engage programming
module clamp
C
Engages and disengages the programming module
clamp each time you press
C
. Optics 22 and 23
should toggle.