User manual

Repair and Replacement Procedures
ProMaster 2500 User Manual 7-3
5. Insert the fuse holder into its slot with the arrow pointing in the same
direction as the arrows on the door and snap the door closed.
Programming Electronics Assembly Replacement
Removing the PE
Follow the steps below to remove the PE assembly from the 2500. The PE
assembly is mounted on the underside of the 2500’s main plate. You will
need to raise the main plate and use a 7/64-inch hex wrench to complete
the removal procedure.
WARNING:This procedure should be performed by a service
technician trained on electromechanical equipment. Do
not attempt this procedure unless you are qualified to do
so. Dangerous high voltages are generated under the main
plate that could cause a harmful electrical shock. Turn off
the 2500 before you begin this procedure.
To help eliminate damage from ESD, wear an antistatic
wrist strap that contains a 1M
(minimum) to 10M
(maximum) isolating resistor. The wrist strap should be
connected to the grounding plug.
1. Turn off the 2500 and remove the power cord.
2. Remove the programming module, if one is installed.
3. Unscrew the two captive hex screws located at the front corners of
the main plate (see Figure 7-3).
4. Lift the main plate until it stops in the fully upright position.
Figure 7-3
Location of the Main Plate Screws
2074-2
MAIN PLATE
MAIN PLATE
SCREW (1 of 2)
HOOD
MAIN PLATE
SCREW
(2 of 2)