User manual
Preventive Maintenance
ProMaster 2500 User Manual 5-67
Maintenance Intervals
Interval Component 2500 Operator 2500 Service
Every Day
Programming module
Track
Beam chuck tips
Optic holes
Beam-to-programming module
alignment
Label path
Clean with air
Clean
Inspect/clean
Inspect/clean
Inspect
Clean
–
–
–
–
–
–
Every Week
Programming module contacts – Clean with DeoxIT
Every Month
(based on 40,000
devices/month)
Dust guards
Operator’s maintenance
(see page 5-55)
Keyboard and display
Beam chuck tips
Labeler ribbon
Label platen area
Programming module contacts
Label print quality
Label platen area
Thermal print head
Clean
–
–
Clean/replace
–
–
–
–
–
–
–
Verify process
Clean
–
Inspect/replace
Inspect/clean
Inspect/replace
Check
Inspect/clean
Clean
Every 6 Months
Beam lead screw
Beam vacuum generator filters
Beam limit bumper feet
DIP programming module contacts
Beam head shafts
–
–
–
–
–
Clean/lubricate
Clean/replace
Replace
Inspect/replace
Inspect/lubricate
Every 2 Years
Print head
Labeler ribbon clips
–
–
Replace
Replace