User manual

Preventive Maintenance
ProMaster 2500 User Manual 5-43
Enter a new number, or accept the default, and press
ENTER
.
The 2500 displays:
Press
START
and the 2500 displays:
When you are finished with the test, press
RESET
.
To Label Devices
If you want to label devices, press
Y
at the
DO YOU WANT TO LABEL?
display. The 2500 displays:
Select the file you want to use, or edit the Temporary file as described
below.
Editing the Temporary File
To create a test label file to be used once (for example, a test file), edit the
Temporary file, which is the first file in the directory. The content of this
file is lost when the 2500 is turned off.
Editing the Temporary file includes selecting the following:
1.
Device package
(either existing or custom)
2.
Type size
3.
Device orientation in input tube
4.
Position of the label
on the device
5.
Device orientation in output tube
6.
Text
Device Package
The 2500 displays:
To select an existing device package, use the arrow keys to move the
display cursor to the type you want and press
ENTER
. Only eight
selections appear on the display at once; use
and
to scroll to the
selections not visible on the display.
CYCLE PARTS
PART TYPE: PLCC 20
PART LENGTH: .390
PRESS START TO BEGIN
CYCLE PARTS
COMM: NO INTERFACE PART TYPE: PLCC 20
PARTS PER TUBE: 5 PART LENGTH: .390
PART TOTAL = 0 PROGRAM TARGET: INF
CYCLE & LABEL
TEMPORARY FILE2 FILE3 FILE4
FILE5 FILE6 FILE7 FILE8
ENTER FILE NAME:
PROGRAM/TEST LABEL TEMPORARY FILE
CUSTOM PLCC 20 PLCC 28 PLCC 32
PLCC 44 PLCC 52 PLCC 68 PLCC 84
MOVE TO SELECTION THEN PRESS ENTER