User manual
Preventive Maintenance
5-40 ProMaster 2500 User Manual
The solenoids perform the following operations (confirm that LEDs on
the solenoids turn on for the duration of each test):
•
Blower
— Turns on low air pressure to the output tracks. There is no
air on the input track.
•
Cutoff
— Turns low air pressure to the beam on and off. If you are
running all tests, perform the cutoff test first when you enter the
diagnostic tests. At the start of the diagnostic tests, the beam should
be up. Pressing
3
directs air to the beam, allowing it to rise.
Note: After you run this test you must press
RESET
to exit the solenoid tests
and then reselect the solenoid tests. If you do not press
RESET
, the Beam
Up/Down and the High Pressure tests will not operate correctly.
•
Beam Up/Down
—Directs low air pressure to raise the beam.
Pressing the
4
key allows the beam to lower.
•
Blow Off
—Turns on low air pressure to the chuck tip to assist in
releasing a device. Feel for air blowing out of the chuck tip.
•
High Pressure
—Turns on high pressure. The beam will lower
quicker than the Beam Up/Down test, which uses low air pressure.
•
Vacuum
—Turns on the vacuum generator. Place your finger over
the end of the chuck and feel the vacuum.
•
Clamp
—Activates the programming module holding clamps. They
should both advance and clamp the module.
To exit the solenoid test and return to the Diagnostic menu, press
E
and
then
ENTER
. To exit the solenoid test and return to the 2500’s main
menu, press
RESET
.
Motor Test
To select Motor Test from the Diagnostics menu, press
3
. The 2500
displays:
WARNING:To perform the motor tests, the hood has to be raised for
better visibility. To avoid electrical shock or mechanical
injury, these tests should be performed only by a service
technician trained on electromechanical equipment.
The beam moves quickly. To avoid injury, keep your
hands, hair, and loose clothing away from the path of the
beam while running these tests.
Refer to the motor test table and Figure 5-17. Press the number for the
motor you wish to test, and then press
START
to activate the motor.
Press
CAL
to reverse the rotation direction.
PRESS NUMBER TO TEST MOTOR, E TO EXIT
1 - BEAM FORWARD 4 - TUBE INPUT
2 - BEAM REVERSE 5 - TUBE OUTPUT
3 - BEAM ROTATION 6 - LABELER