User manual

Preventive Maintenance
ProMaster 2500 User Manual 5-3
3. The tube is shaken by the input orbital assembly to help devices slide
from the tube onto the input track. The base of the input tube clamp
is mounted to a plate. The orbital disk mounting shaft is drilled off-
center and acts as a cam against the plate.
The disk, which is clamped to the motor, rotates causing the plate to
jog back and forth (following the slight cam). As the input orbital
motor rotates at speed, it generates vibration to prod devices from the
input tube.
Figure 5-1
Optic and Microswitch Locations
1939-1
1
15 (Under main plate)
2
17
3
4
13
14
20 (Output tube 1)
21 (Output tube 2)
19
11
12
16 (Under main plate)
22