User manual

Operation
ProMaster 2500 User Manual 4-31
4. Press
START
. The beam rotates the device 90
°
and moves it over the
programming module. Push the beam down manually (on either side
of the beam limit bar), and ensure that the device moves into the
center of the programming module’s block.
When the alignment is correct, press and hold
D
on the 2500
keyboard to check the device’s insertion.
Repeat steps 1 through 4 until the device moves into the center of the
programming module and does not rub one set of contacts more than
another.
5. When the alignment is correct, press
START
to continue running the
Task.
Figure 4-25
Device too Close to the Front
Figure 4-26
Device too Close to the Back
If the device was too close to the FRONT, move the beam to the RIGHT.
1860-2
X4
X1
X3
FRONT
If the device was too close to the BACK, move the beam to the LEFT.
1861-2
X4
X1
X3
BACK