Specifications
TME-EPIC-HURLX-R3V5.docx
Rev 3.5
Page 31 of 49
3.23 Analog Inputs and PWM Outputs (J12, Top)
Connector type: IDC40 pin header 2.00 mm
Matching connector:
Pin
IDC40 pin female connector 2.00 mm
Signal Pin Signal
1 +5 Volts 2 +5 Volts
3 +5 Volts 4 +5 Volts
5 NC 6 SIO_AGND
7 SIO_PWM2 8 SIO_AGND
9 SIO_PWM3 10 SIO_AGND
11 SIO_PWM4 12 SIO_AGND
13 SIO_PWM5 14 SIO_AGND
15 SIO_ADC0 16 SIO_AGND
17 SIO_ADC1 18 SIO_AGND
19 SIO_ADC2 20 SIO_AGND
21 SIO_ADC3 22 SIO_AGND
23 SIO_ADC4 24 SIO_AGND
25 SIO_ADC5 26 SIO_AGND
27 SIO_ADC6 28 SIO_AGND
29 SIO_ADC7 30 SIO_AGND
31 SIO_ADC_VREF 32 SIO_AGND
33 +3.3 Volts 34 SIO_AGND
35 +3.3 Volts 36 SIO_AGND
37 GND 38 GND
39 GND 40 GND
3.24 REQ#/GNT# Select Panel (J5=REQ#, J6=GNT#, Top)
Connector type: IDC12 pin header 2.00 mm.
Matching part:
2.0 mm jumper
1 2 LAN 1
st
Bus Master
3 4 Mini PCI
5 6 4
th
PC104+
7 8 LAN 2
nd
Bus Master
9 10 Mini PCI
11 12 4
th
PC104+
These Jumper Fields are to select two out of three PCI device to act as Bus Masters. By default the Ethernet
controller and the Mini PCI extension card act as Bus Masters. In case a 4th Bus Master is needed at the PC104+
Bus, switch Jumper to desired setting. Note that Jumpers on J5 and J6 must be in the same positions.