PLR580D / DA User Guide
(4) Point-to-Point Remote/Repeater
Do not use this mode with the PLR580
(5) Point-to-Point Repeater
Do not use this mode with the PLR580
If a repeater is need in the system do not use a PLR580D or PLR580DA. If and extended range of non-line-of-sight
situation exists, use the Data-Linc Group PLR5000 radio modem as a repeater. When designated as a repeater, a
radio modem behaves as a pass-through link. All settings for the call book, baud rates, and radio transmission
characteristics are disabled. A repeater will connect with any master that calls it (the repeater must still be set up
in the master’s call book).
(6) Point-to-Point Remote/Master Switchable
Do not use this mode with the PLR580
(7) Point-to-Multipoint Repeater
Can be used as a repeater / remote in a multipoint network. Please contact Data-Linc Group for detailed information
on this setting.
Main Menu Option (1): Set Baud Rate
The PLR580 use 8 Data Bits/ no Parity, 1 Stop bit only. Do not change. These settings are not used when setting
radio operating values. The default setting is 0 (8,N,1).
Note: The RF parameter baud rate must match the internal set baud rate in the EEprom. A mismatched baud
rate will cause communication to alway stop.
ModBus RTU
Do not use this mode with the PLR580.