User`s guide

38 DL-WINDOWS™ V4.0 USER'S GUIDE
Checking this box will cause the lock to unlock when a short is
maintained across the remote input. The lock will remain unlocked until
the next User Code entry, at which time the lock will lock. See WI1844
for additional information.
Checking this box will cause the lock to lock when a short is maintained
across the remote input. The lock will remain locked until the next User
Code entry, at which time the lock will return to Passage Mode. See
WI1844 for additional information.
For use with DL-WINDOWS software. The remote input will act as User
298 or keypad Function 58. See page 8 for details regarding keypad
Function 58. Not for use with wireless Networx
series locks or
devices.
If enabled, the remote input will toggle Passage Mode. Passage Mode
allows passage through the door without the need for a User Code.
Remote input disables the lock while a short is maintained across
remote input. Therefore, if a switch is used for the remote input, as long
as the switch is closed the lock will be disabled and its state cannot be
changed. As long as the switch is open, the lock will be enabled. See
WI1844 for additional information.
This screen is used to program Remote Input Functions. Note: Remote Disabled Lock, Forced Lock Follows Remote or Forced Unlock
Follows Remote should only be used with external power to the lock. Note: These Remote Release Functions are not available for use with the
wireless Networx
system.
Remote input is enabled and will cause the door to momentarily unlock.
Select one of the Remote Input Functions below.
Remote Release (Momentary)
Remote Toggles Passage Mode
Remote Disables Lock
Forced Lock Follows Remote
Forced Unlock Follows Remote
Remote Puts Lock in PC Comm Mode
"Programmable Features" Screen - Remote tab