User`s guide

DL-WINDOWS™ V4.0 USER'S GUIDE 37
Relay will activate when lock is unlocked. Relay power must be
provided from an external power supply. If Relay follows Lock/Unlock
Status is selected, the relay will remain activated as long as the door is
unlocked. This feature supersedes all other relay options.
Will activate relay if the lock has been unlocked by a programmed
schedule.
The Features screen is used to program Relay Functions and other programmable Features. If programmed, one or more of the following relay
Functions will activate an external Relay for an interval of 3 seconds, if the condition is met. If Relay follows Lock/Unlock Status is selected, the
relay will remain activated as long as the door is unlocked.
Will activate relay when the Remote Release is activated. This will
provide an alert that access has been granted via the Remote Release.
Will activate relay if a User enters their User Code while that User Code
is disabled. Provides an alert that a disabled Use Code entry has been
detected.
Will activate relay when the Remote Release is attempted to be
activated but is disabled. This will provide an alert that an unsuccessful
access has been attempted via the Remote Release.
Will activate relay if any unsuccessful Use Code entry occurs. This will
provide an alert that an unauthorized Use Code entry has been detected.
Will activate relay anytime a User enters a valid User Code and is
granted access.
Will activate relay if the lock has been programmed for Scheduled Relay
Activation (Group 1 Initiated) and a member of Group 1 has entered
their User Code within the required window.
Will activate relay if the lock has be locked by a programmed schedule.
Will activate relay if the Ambush Code is entered followed by a valid
User Code.
Will activate relay if the number of User Code entry attempts has been
exceeded and the keypad is locked out.
Will activate relay any time a key is pressed or a proximity card is
presented
Select any of the Functions below to Activate the Relay Output (more than one may be selected).
For use with the NETWORXPANEL (see OI352). Relay will activate
when Door is found to be left open after a specified period of time (see
the Options tab and the Door Ajar feature description on page 35). If
Activate Relay On Door Ajar is selected, the relay will activate for two
seconds. With the NETWORXPANEL, see WI1855, Function 67
(features 12, 40 and 41).
Remote Input While Enabled
Remote Input While Disabled
Failed Entry Attempt
Disabled User Entered Code
Authorized Entry
Scheduled (Group 1 Activated)
Locked by Schedule
Unlocked by Schedule
Lockout # of Attempts Exceeded
Ambush Function Activated
Any Keypress of Card Entry
Relay follows Lock/Unlock Status
Activate Relay on Door Ajar
"Programmable Features" Screen - Relay Functions tab
For use with the Networx
NETWORXPANEL control panel. See
OI352 for more information regarding the wireless Networx
system
and its supported features, including "Two Door Mode".
Two Door Mode