30 DL-WINDOWS™ V4.0 USER'S GUIDE
"Set Double Sided Access" Entry Side Selection
LockID
Displays the LockID number selected
in the Global Users screen before the
Set Double Sided Access button was
clicked.
The Alarm Lock Trilogy 5200 series and 5300 series locks are double-sided to allow control entry and exit. Since either side of the
door is "protected", the idea of an "inside" or "outside" may not always apply. The installation instructions for the 5300 series locks
differentiate between the two sides of the lock by using the terms "primary" side and "secondary" side.
• The primary side of the lock contains the ribbon cable; inserting the metal key into its lock cylinder will always unlock the latch,
allowing entry or exit.
• The secondary side contains no wires; inserting the metal key into its lock cylinder will NEVER unlock the latch. The key inserted
into the secondary side ONLY allows removal / installation of the secondary side lever. After programming with DL-Windows, be
sure to test access on both sides of the door.
Shown at bottom is an example double-sided lock (PDL5300). Note: This screen is also used with the Networx
™
NETWORXPANEL
control panel and "Two Door Mode"; see OI352 for more information regarding the wireless Networx
™
system and its supported
features.
Pri. Side
To add the selected User to the "Primary Side" of
the lock (selected User's User Code pressed at this
side will unlock the lock), double click the "P" box to
turn its color green.
You can also press and hold the Ctrl keyboard key
and single-click the "P" box to turn its color green.
Sec. Side
To add the selected User to the "Secondary Side" of
the lock (selected User's User Code pressed at this
side will unlock the lock), double click the "S" box to
turn its color green.
You can also press and hold the Ctrl keyboard key
and single-click the "S" box to turn its color green.
Add Selected Users to Selected Sides
Click to add the selected User(s) to the sides of
the lock displayed in green color.
Accept
Click to add the selected User
(s) to the sides of the lock
displayed in green color and
to close this dialog.
Cancel
Click to close dialog
without saving
changes.
PDL5300 PRIMARY SIDE PDL5300 SECONDARY SIDE
Standard red and
black download com-
munication port (PC /
AL-DTM Interface)
Three-color Status LED
Infrared Transmitter
LED for printer
This key lock cylinder
ONLY removes this
handle (does not
unlock the lock--use to
change batteries)*
Battery Pack inside
This key lock cylinder
unlocks the lock*
(No communication
port Interface)
Proximity Card
Readers
* Note: Only the Primary Lock Side key cylinder allows non-logged access; the Secondary Lock Side
cylinder is only used to secure the housing to the door. Therefore a person in possession of only the
metal key on the Secondary Lock Side has no means of unlocking the PDL5300 lock.
Red LED