User`s guide

DL-WINDOWS™ V4.0 USER'S GUIDE 27
Transferring Data from AL-DTM to Locks for the first time
1. Connect the AL-DTM to the Lock. Connect the double-ended
banana plug into the AL-DTM and into the lock that is to be
programmed (observing proper tab direction).
2. The AL-DTM will display the LOCK MODE screen, press the
green button to toggle through the following screens:
3. Toggle screens to display DOOR SELECT MODE, then select YES
by pressing the left AL-DTM button.
4. The screen displays “Set Door TO=0001”. The number "0001"
refers to the lock assigned LockID # 1 in DL-Windows. If this is
the first lock to be programmed, press the green button (SET).
(To choose a different lock, the left AL-DTM button will toggle
back through the list of locks and the middle button will toggle
forward).
5. The screen displays “Ready, Door=xxxx” (xxxx = LockID).
Press left button (GO) and the screen will then switch between:
6. Enter the User 299 User Code at the lock keypad. The AL-
DTM briefly displays a message that it is "Analyzing Lock –
Please Standby" and then displays the following:
7. Do not press any more buttons, and the AL-DTM will display the
following:
The Lock will continue to beep while in communication with the
AL-DTM. After programming is complete, the following will
display:
8. Program Additional Locks. Repeat Steps for each lock to be
programmed. Make sure that each Lock is being assigned the
correct LockID. This will ensure that the locks are programmed
Re-enter 299
Code to Continue
Door 0001, Send
PGM Packet 001
Packet Numbers will go up until all packets have been transferred to the
lock. PDL3000 locks will take longer due a larger number of packets
(typically 5 times longer than DL3000 or DL3500 locks.
Send Data from the AL-DTM to the Lock
COMM. COMPLETE,
07/24/01 02:08PM
LOCK’S TIME AND
DATE UPDATED.
0993 FREE
MEMORY BLOCKS
(Current date and Time)
(Current Memory Status)
Waiting for lock
04/25/06 02:30PM
DTM-III: Plug in
then enter code
as they were set up in DL-Windows as well as ensuring the
correct data transfer for all subsequent communication
attempts.
If the lock's Master Code and the DL-Windows Master Code do
not match, then the following AL-DTM screen will display:
In this case, the solution is to either use the lock keypad to re-
program the Master Code--or--re-configure the AL-DTM (using
DL-Windows) so that both Master Codes match.
After the initial programming of the locks with the AL-DTM, Door
Select Mode is no longer required. AL-DTM should now be used
in Standard Mode (Lock Mode). All changes can be
communicated to and from the locks in this mode.
DL2800/ DL3000 Only
PC COMM MODE
11/28/06 02:23PM
DOOR SELECT MODE
YES NO
LOCK MODE
YES NO
MASTER CODE
MISMATCH!
DOOR 03, SENDING
PGM PACKET 000
Transferring Data from AL-DTM to Locks (Changes)