User guide

DATA-LINC GROUP
4
PN 161-09996-003A
rev 9/03
CCS9000 User Guide
the four individual ports.
CCS9000 Master Units
The CCS9000 Master units consist of Data-Linc Group’s DLM4100 series for dial-up and leased line, and the SRM6000
for radio. Each is factory configured to operate with the CCS9000 system.
CCS9000 Remote Units
Each remote CCS9000 has a unique firmware imbedded five digit address and configuration that is factory programmed
into. The address can be found on the outside of the enclosure and on the controller board inside of each unit. The
configuration is dependant upon the model of modem ordered and is not user accessible.
A diagram of this pin out of the DB9 connector is provided in the appendices. Port baud rate settings are selectable with
the CONNECT software application.
A feature unique to the DATA-LINC GROUP CCS9000 remote is its gateway port connector. The 6 pin mini-din connector
on each remote is designed to integrate a secondary CCS9000 master allowing the seamless integration of different
communication media. The integration is accomplished entirely through the use of firmware and the CONNECT software,
there is no user hardware configuration needed. All units shipped from the factory with the gateway capability. Connecting
the cable supplied with each auxiliary master to the gateway port is all that is required.
The barrel connector on each remote is for 9 volt ac power.
There are LED indicators on each remote which provide diagnostics for the following:
Red Speaker (Dial Up and Leased Line Only)
Red Power Indication
Yellow Data Out of active port
Green Data In the active port
Amber Tone Detection (Leased Line Only)
Amber Carrier Detection
Green Indicates Port 1 is active
Green Indicates Port 2 is active
Green Indicates Port 3 is active