User Manual
AlarmView™ System Administrator’s Manual
880-0326-01 REV. A Page 19
Transmitter
Parameter Setting
Physical Dimensions 5.25” x 1.5” x 3”
(13.3 x 3.8 x 7.6 cm)
Battery Life 2 years of normal operation
Battery Operation Approximately 45 minutes
Output Power 400 mW nominal
555 mW maximum
Frequency Range 450 MHz to 466 MHz
Typical Range
(no intervening structures)
Approx. 150 ft (46 m)
Input Voltage +15V DC, 1.5 amps
Antenna Terminal Designed
Impedance
50 ohms
Temperature Range
(normal operation)
32º F to 113º F (0º C to 45º C) at 5% to
95% RH, non-condensing
Temperature Range
(storage)
-4º F to 140º F (-20º C to 60º C) at 5%
to 95% RH, non-condensing
Altitude
(normal operation)
0 ft to 10,000 ft (0 m to 3,048 m)
Mechanical Shock IEC 68-2-27
Water Resistance
(transmitter, not power supply)
IEC 529 Class IPXI
Radiated Immunity
(radio-frequency electromagnetic
fields)
Up to 3V/meter from 80 MHz to 1
GHz
Conducted Immunity
(conducted-frequency
electromagnetic energy)
MIL-STD-461D
CSI14 Level 3
FCC Compliant FCC Part 90