PN: GCU-2K1-UG:RevI.2 NGC
GCU2K1 Specifications
6.4 MECHANICAL DIMENSIONS
Description
Dimension
Width 63.5 x 43.2 x 7.62mm
(2.5” x 1.7” x 0.3”)
Weight 94 grams (3.2 ounces)
Mounting Holes #2 SAE hardware
Table 4 Mechanical Dimensions
6.5 ELECTRICAL SPECIFICATIONS
Description Specification
Voltage(s) +28Vdc
9
Current(s)
or +5V +/-15V
240ma (idle) to 500ma (max. rate)
Gyro Control Loop Bandwidth 200hz (typical)
Maximum Rate Response 150deg/sec
Table 5 Electrical Specifications
6.6 ENVIRONMENTAL SPECIFICATION
Description
Specification
Operating Limits -40 to +80deg C
Relative Humidity 0 to +95 % relative humidity
(non condensing)
Storage Limits Same and Operating
Table 6 Environmental Specifications
9
When used with the optional DC-DC converter GCU2K1-PS