User`s guide
Gyro Control Unit (GCU)
User’s Guide
17
MaxMetrix, Scottsdale, AZ
PN: GCU-2K1-UG:RevI.2 NGC
4 PERFORMANCE ANALYZER
A Microsoft Windows compatible software application provides the user the ability to observe the G-2000
performance, as well as, adjust and store several of the key tuning parameters in the GCU FLASH memory.
Operating System Requirement:
• Windows Compatible Processing Platform running Windows XP or equivalent.
4.1 PERFORMANCE ANALYZER (GYRO SETUP PROGRAM)
The Gyro Setup program is organized as a main window with several tabs to individual functions. The
application is organized into the following tabs.
1. CAL / STATUS
2. NOTCH FILTERS
3. SCOPE
4. SPECTRUM ANALYZER
5. BODE PLOT
6. LOADER
To begin, the user should select the CAL / STATUS tab and request a status report command. After doing
so, the GCU should reply with the current software revisions for the individual programmable devices. The
user should then request the GCU to report back the current control loop parameters by selecting the “Read
Gyro Contents” command button. At this point, the Calibration Coefficients for the GCU unit are filled in
for inspections. Most values can be modified and sent to the GCU module. If the user desires to save these
values in the GCU flash memory they can select the “Save Calibration” command.