User`s guide
Gyro Control Unit (GCU)
User’s Guide
11
MaxMetrix, Scottsdale, AZ
PN: GCU-2K1-UG:RevI.2 NGC
1.4.2 ANALOG INTERFACE
The analog outputs are scaled ±10V for an associated rate input of ±200°/sec.
Figure 11 Analog Output Connector
Part Number Description
DF13 – 4P – 1.25H(50) Board Connector
DF13 – 4S – 1.25C Mating Connector
DF13 – 2630SCFA CRIMP PIN
Pin Number Description
1 YAW
2 NO CONNECTION
3 SIGNAL GROUND
4 PITCH