Owner`s manual
VENTING (Vertical with Decreaser)
For each additional elbow used after the first elbow, 3 ft. (914 mm) must be subtracted from the maximum venting allowed. For each
45° elbow used, 1-1/2 ft. (457 mm) must be subtracted from the maximum venting allowed.
NOTE: (2) 45° degree elbows may be used in place of (1) 90° elbow.
MAXIMUM VERTICAL &HORIZONTAL
COMBINATION VENTING WITH
WITH 8” x 6-5/8” DECREASER
VERTICAL & HORIZONTAL COMBINATION TERMINATIONS
CAUTION: This gas
appliance must not be
connected to or joined with
any other chimney flue
serving another appliance.
MAXIMUM VERTICAL & HORIZONTAL
COMBINATION VENTING
5” x 8”
NOTE: Horizontal sections
require 1/4” (6 mm) rise for
every 12” (305 mm) of travel.
PAGE 30
Depending on your particular venting needs,
a Decreaser may be necessary to terminate
the venting system.
20 FT
(6.10 m)
20 FT
(6.10 m)
IMPORTANT: A WALL THIMBLE PASS-THRU
MUST BE USED ON ALL HORIZONTAL VENT RUNS.
IF USING A 8” x 6-5/8” DECREASER FOLLOW VENT
PIPE MANUFACTURER‟S INSTALLATION
INSTRUCTIONS FOR THEIR WALL THIMBLE.
20 FT
(6.10 m)
20 FT
(6.10 m)
90° ELBOW 90° ELBOW
TERMINATION CAP
TERMINATION CAP
8” x 6-5/8” DECREASER
NOTE: Pages 27-28 have information
on restrictor installation in
conjunction with venting installation.
Page 49 has information on restrictor
recommendations depending on burner flame
appearance and instructions on installation after
venting is completed.
6” (152 mm)