CONVERSION KIT INSTRUCTIONS  
  NATURAL GAS  LP GAS 
MINIMUM INLET GAS PRESSURE  5” WC (1.25 kPa) (7” WC (1.74 kPa) recommended)  11” WC (2.74 kPa) (recommended) 
MAXIMUM INLET GAS PRESSURE  10.5” WC (2.62 kPa)  13” WC (3.24 kPa) 
MANIFOLD PRESSURE (HI)  3.5” WC (.87 kPa)   10” WC (2.49 kPa) 
MANIFOLD PRESSURE (LO)  1.6” WC (.40 kPa)  6.4” WC (1.59 kPa) 
CONVERT THE GAS CONTROL VALVE: 
Follow stepper motor pressure regulator instruction sheet included with conversion kit to 
convert gas valve.   ( L P   o r   N A T   m a r k e d   o n   s t e p p e r   m o t o r   p r e s s u r e  
regulator).   
COMPLETE THE CONVERSION: 
1.  Adjust venturi on burner tube to correct setting by loosening screw, adjusting cap 
and retightening screw. CORRECT SETTINGS: NAT. : 1/16” (2mm) open 
                         L.P. : 1/2” (13mm) open 
2.  Re-install burner /burner heat shield assembly into fireplace, checking to ensure 
burner venturi is properly seated over burner orifice. 
3.  Re-install pilot shield, ember refractory and logs. 
4.  Light pilot and turn burner on following instructions as outlined on pages 11-12. 
5.  Check for leaks at all connections with soapy water, whether field or factory made. 
6.  Test both inlet and manifold pressures. Page 13. Chart below states proper pressure 
readings. 
7.  Visually  check  pilot  flame.  Flame  should  envelope  top  of  thermocouple  and 
thermopile  3/8”  (10mm)  to  1/2”  (13mm),  and  extend  onto  burner  far  enough  for 
proper ignition.   
To Adjust pilot:  Remove pilot adjustment screw from gas valve.  Turn inner pilot 
adjustment  screw  clockwise  to  decrease  or  counter-clockwise  to  increase  pilot 
flame.  Re-install  pilot  adjustment  screw  cover  and  tighten. 
8.  Turn burner and pilot off. 
9.  Affix Gas sticker over existing label on metal tag. 
10.  Re-install glass frame assembly, upper louver and upper hood. 
11.  Verify proper ignition and operation of fireplace. Refer to page 18 for proper pilot 
and burner flame appearance and adjustment. 
12.  Complete and affix Gas Conversion as close to gas valve as possible. 
Figure 17b 
PROPER BURNER / PILOT ORIENTATION 
(Your pilot may look slightly different than one shown) 
Figure 17a 
GAS CONVERSION LABEL  
(included with conversion kit) 