Installation manual
16
CONVERSION KIT INSTRUCTIONS
FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If
flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
WARNING Burner tube adjustable venturi positioning should only be performed by a qualified professional service technician.
Figure 16a
Lazy yellow flames - ideal
Short blue flames
venturi open too far
Dark orange flames / black tips
Venturi closed too far
Excessive burner media
Lifting (ghosting) flames
Improper Venting
Gas pressure too high
Correct pilot flame
Figure 16b
1. Remove upper louver and hood.
2. Remove glass frame assembly.
3. Remove log set.
4. Remove pilot shield.
5. Remove burner / burner heat shield assembly.
6. Loosen screw on burner venturi and adjust as necessary. Tighten screw.
7. Reinstall all components previously removed.
8. Light fireplace and wait 15 minutes before determining if any further adjustments are needed.
TO ADJUST VENTURI:
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
VENTURI POSITION FLAME COLOR VENTURI ADJUSTMENT
Closed too far Dark orange flame with black tips Open venturi setting slightly
Open too far Blue flames Close venturi setting slightly
BURNER VENTURI
Figure 16c
IMPORTANT
SLIGHT ADJUSTMENTS TO BURNER VENTURI OPENING CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT
INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES
AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
WARNING To avoid property damage or personal injury, allow fireplace ample time to cool before making any adjustments.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS LP (PROPANE) GAS
1/16” (2mm) OPEN 1/2” (13mm)