Installation manual
1
SPECIFICATIONS
DSL-36
NATURAL GAS LP GAS
MINIMUM INLET GAS PRESSURE 5” WC (1.25 kPa) (7” WC (1.74 kPa) recommended)
11” WC (2.74 kPa)
(recommended)
MAXIMUM INLET GAS PRESSURE 10.5” WC (2.62 kPa) 13” WC (3.24 kPa)
MANIFOLD PRESSURE (HI) 3.8” WC (.95 kPa) 10” WC (2.49 kPa)
MANIFOLD PRESSURE (LO) 1.1” WC (.27 kPa) 6.3” WC (1.57 kPa)
ORIFICE SIZE #42 #53
INPUT BTU/hr. (kW) 26,000 BTU/hr (7.62 kW) 25,500 BTU/hr (7.47 kW)
MINIMUM INPUT BTU/hr. (kW) 13,000 BTU/hr (3.81 kW) 12,000 BTU/hr (3.52 kW)
#DSL-36 COMPONENTS LIST
PART NUMBER DESCRIPTION
DSL-770 Millivolt Board Assembly
700-203 Manual Gas Shut-off Valve
DSL-135 Burner / Log Grate Assembly
DSL-500 Log Package
DSL-057T Glass Frame Assembly
OCK-S53 LP Conversion Kit
600-083 Receptacle/Speed Control Assembly
942-085 5” Restrictor Plate
DSL-HHS Horizontal Vent Heat Shield
500-PRC 3 pc. Grill Assembly
DSL-FPS Firepro Standoff