Installation manual

27
CONTROL BOARD REMOVAL / INSTALLATION
1. Turn fireplace off.
2. Shut off gas supply at manual shut-off valve.
3. Disconnect gas line flex tube from manual shut-off valve.
4. Disconnect any wall switch, remote control or thermostat wires from top & bottom
terminals on gas valve or unplug all components from receptacle, disconnect all
wiring harnesses attached to gas valve.
5. Remove upper hood, upper louver, lower grill and glass frame assembly.
6. Remove logs, bottom refractory panels and refractory panel set.
7. Remove pilot shield.
8. Remove burner / burner heat shield assembly by lifting up off the orifice and out of
firebox.
9. Remove and save (8) screws securing control board, lift board out of firebox being
careful not to damage sealing gasket lying underneath.
BURNER HEAT SHIELD
BURNER
PILOT SHIELD
PILOT
ASSEMBLY
ORIFICE
CONTROL BOARD REMOVAL
CONTROL BOARD INSTALLATION
1. Install control board,, aligning holes in control board with holes in firebox bottom.
Secure to firebox bottom with (8) screws previously removed.
2. Install burner / burner heat shield assembly, making sure burner venturi is seated
over burner orifice and pilot assembly is above burner.
3. Reinstall refractory panels (if applicable), pilot shield, bottom refractory panels and
log set.
4. Reconnect gas line to manual shut-off valve.
5. Reconnect any wall switch, remote control or thermostat wires to top and bottom
terminals on gas valve or re-connect all wiring harnesses to gas valve. Plug all
components into electrical outlet.
6. Reinstall glass frame assembly, upper louver, upper hood and lower grill.
7. Turn gas on. Verify proper log placement, operation of fireplace, and any
electrical components.
Figure 27a
WARNING
DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET
(LOCATED UNDER CONTROL BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION
If burner and/or pilot have been burning, use appropriate protection to
avoid burns or personal property damage before removing any components.
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS WITH SOAPY WATER, WHETHER
FIELD OR FACTORY MADE.
NOTE You components may look slightly different than ones shown.