Installation manual
17
HORIZONTAL VENT HEAT SHIELD
VENTING
HORIZONTAL VENTING
TYPICAL CORNER INSTALLATION 5” X 8”
90° elbow + horizontal pipe+ termination cap.
(Horizontal Vent Heat Shield required).
1. Loosen, but do not remove center three screws on top of fireplace.
2. Bend horizontal heat shield at perforation to a 90° angle. Slide (3) slots on horizontal vent heat shield under loosened screws.
3. Re-tighten screws.
PIPE
90° ELBOW
Vent Opening Dimensions: 12-1/2” (318mm) H x 10-7/8” (276mm)
From Floor or Hearth to Vent Opening Center: 37-7/8” (962mm)
From Corner to Vent Opening Center: 15-7/8” (403mm)
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS USING 5” x 8”
TERMINATION CAP
ATTACHMENT SCREWS
Figure 17b
Figure 17a
IMPORTANT
The horizontal vent heat shield must be installed when using a 90-degree elbow to horizontally position the vent system.
This includes any corner installation.
NOTE Horizontal sections require 1/4” (6mm) rise for every 12” (305mm) of travel.