GAS LINE CONNECTION  
This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions included 
with conversion kit if converting to LP gas. 
GAS CONVERSION 
ATTENTION 
The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in 
accordance with the requirements of the ANSI Z223.1 installation code. 
CAUTION 
 Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.  
 If not, follow ANSI 223.1. 
Commonwealth of Massachusetts: Installation must be done by a licensed plumber of gas fitter. 
NOTE 
A  listed (and Commonwealth  of  Massachusetts  approved)  1/2”  (13mm) T-handle manual  shut-off  valve  and  flexible  gas 
connector (included) are connected to the 1/2” (13mm) control valve inlet. If substituting for these components, please consult 
local codes for compliance. 
This fireplace is  equipped with a 3/8” (10mm)  x 18”  (457mm)  long flexible gas  connector and  manual shut-off valve. The gas 
line should be run to the point of connection where the shut-off valve and flexible gas line will connect. 
The  appliance  and  its  individual  shutoff  valve  must  be  disconnected  from the  gas  supply  piping  system during  any  pressure 
testing of that system at pressures in excess of ½ psi (3.5 kPa). 
The appliance must be  isolated  from  the  gas  supply piping system by  closing its  individual manual shut-off  valve during any 
pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa). 
For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating  methods. 
ATTENTION 
HIGH ALTITUDE INSTALLATIONS 
In  the  USA:    The  appliance  may  be  installed  at  higher  altitudes.  Please  refer  to  your  American  Gas  Association  
guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000ft. (610m) 
is to be reduced 4% for each 1000ft. (305m) above sea level. Refer also to National Fuel Gas Code, ANSI Z223.1/ NFPA 
54, local authorities, or codes  which have jurisdiction in your area  regarding the de -rate guidelines. 
In Canada: When the appliance is installed at elevations above 4500ft. (1372m), the certified high altitude rating shall 
be reduced  at  the  rate  of 4%  for  each  additional  1000ft. (305m). Refer  also  to CSA-B149.1  Natural  Gas and  Propane 
Installation  Code,  Local  authorities,  or  codes  which  have  jurisdiction  in  your  area  regarding  the  de-rate  guidelines. 
  NATURAL GAS  LP GAS 
MINIMUM INLET GAS PRESSURE  5” WC (1.25 kPa) (7” WC (1.74 kPa) (recommended)  11” WC (2.74 kPa) (recommended) 
MAXIMUM INLET GAS PRESSURE  10.5” WC (2.62 kPa)  13” WC (3.24 kPa) 