Installation manual

11
MANTEL REQUIREMENTS
TYPICAL INSTALLATION OPTIONS
15-1/2”
(394mm)
36-3/8”
(924mm)
1/4”
(6mm)
1/4” (6mm)
29-78”
(759mm)
42-1/2”
(1073mm)
59-3/4” (1517mm)
15-1/2”
(394mm)
36-3/8”
(924mm)
1/4”
(6mm)
HORIZONTAL INSTALLATION
CORNER INSTALLATION
VERTICAL INSTALLATION
10"
254mm
22"
559mm
16"
406mm
3/4"
19mm
4"
102mm
14"
356mm
Clearance to mantel legs or wall projections
(acceptable on both sides of opening).
Horizontal vent heat shield
IMPORTANT
Kozy Heat wall thimble pass-thru (#800-WPT or #800-WPT2) must be used on all horizontal vent runs.
Follow instructions on page 15 of this installation manual.
The horizontal heat shield included with this fireplace must be installed when using a 90-degree elbow directly off top of unit to
horizontally position vent system.
Horizontal vent heat shield not shown in illustrations below for clarity purposes only.
Figure 11b
Figure 11a
WARNING
Non-combustible zone: No combustible materials allowed on top of fireplace within shaded area for entire width and
depth of fireplace with the exception of the header. Backside of header must be no more than 2-1/4(57mm) from front
of fireplace.