Installation manual
9
37-1/2”
(953mm)
36-3/8”
(924mm)
WALL ENCLOSURE ROUGH OPENING
12-1/2” (318mm) H x 10-7/8” (277mm) W opening
(required for horizontal terminations)
Figure 9a
(APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS)
37-1/2” (952mm) High x 36-3/8” (924mm) Wide x 15-3/4” (400mm) Deep.
1/4” (6mm) clearance at back and sides of fireplace must be maintained.
MINIMUM FINISHED OPENING DIMENSIONS
WALL ENCLOSURE ROUGH OPENING
IMPORTANT
Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust rough
opening size as necessary to maintain at least minimum clearance requirements.
Non-combustible facing material may be applied over (but not directly to) fireplace face. This will prevent facing material from
falling off due to heat expansion. Do not obstruct the flow of ventilation air.
NOTE Provide adequate clearance in front of fireplace to access components.
WARNING
DO NOT OBSTRUCT UPPER AND LOWER GRILL OPENINGS. ROOM AIR ENTERS THROUGH LOWER PASSAGE, IS HEATED
AND EXITS THROUGH UPPER PASSAGE. BLOCKING THESE PASSAGES MAY RESULT IN OVERHEATING, CREATING A
POTENTIALLY HAZARDOUS SITUATION.
FRAMING