User Guide User Manual
Emulations User guide
164
LC printing Certain professional applications may require unusually large char-
acter sizes. Therefore your printer has the possibility of scaling stan-
dard size characters up to factor 99 by means of control sequences
(LCP*).
The Header sequence defines the parameters (e.g. height) once.
This definition remains until the printer is switched off.
The printable LCP* information is transmitted in an LCP “bracket”
(SI).
The following character sets (with national characters) are available:
The character sets are selected via the following LCP sequence
ESC ”P“ ”L“ ”S“ n ESC ”\“. The value of n may range between 01 and
02 (as ASCII characters) – see ID column in the above table.
To select e.g. the german character set, you must use the following
data set:
The printout of LCP characters can be selected in all of the
emulations. Prerequisite: Printer must be in Barcode mode.
Note that this printer supports some scalable fonts in the
LQ-2170 emulation if a compatible driver is used.
* Large Character Printing
ID 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E
US ASCII 01
#$@[\]?`{|}¯
GERMAN 02
#$§ÄÖÜ?`äöüß
ASCII ESC P L S 0 1 ESC \
hex. 1B504C5330311B5C
dec. 2780768348492792