The QuickStatus command
SkyZhone 45 Installation Guide
51
D
R
AFT
TSSI = _00 A HEX value for TSSI, which is the current transmit
output level. This should be less than the Transmit Signal
Strength Threshold.
KTSSI=20 The HEX setting for transmit threshold constant is
currently 20
PRIFREQ=A01 The primary frequency is channel A01
SECFREQ=A13 The secondary frequency is channel A13
TEMP=_00 A HEX value for the current temperature inside the IDU.
KTEMP=20 The HEX setting for the temperature constant is 20.
FREQ= _000 The current channel setting, which may be the PRIMARY
or SECONDARY frequency.
LOCK=_YES Gives condition of frequency lock. Normal is “YES” and
the other indication is “NO”.
PA=_ON Gives status of power amplifier. Normal is “ON” and the
other indication is “OFF”.
LOOP=_OFF Indicates if Loop Back testing is in progress. Normal is
“OFF” and the other indications is “ON”.
VMON=_OK Indicates voltage monitors are operational. Normal is
“OK” and the other indication is “ALT” for Alert.
Table 17: Status readout