User's Manual

Table Of Contents
Verifying the installation
SkyZhone 45 Installation Guide
49
D
R
AFT
WARNING! Do not perform this command unless the antenna is
clear of people, properly mounted, and connected to the ODU
The following example sets the transmit and receive amplifiers to ON :
@ S A 0 O N 0 0 0 ! <Enter>
The first three characters @ S A begins the command string for the set
amplifiers command.
The fourth character, 0, defines the unit number, which is always zero.
The fifth and sixth characters are O N (letters), which set the amplifiers to
ON.
The seventh, eighth and ninth characters are 0.
The last two keystrokes of the command are ! <Enter>.
Setting the amplifiers OFF
This command turns off the power to the receive and transmit amplifiers,
disabling the link.
The following example sets the transmit and receive amplifiers to OFF:
@ S A 0 O F 0 0 0 ! <Enter>
The first three characters @ S A begin the command string for the set
amplifiers command.
The fourth character, 0, defines the unit number, which is always zero.
The fifth and sixth characters are O F (letters) which set the amplifiers to
OFF.
The seventh, eighth and ninth characters are 0.
The last two keystrokes of the command are ! <Enter>.
Verifying the installation
After the provisioning is complete, the link should be transmitting, and if the
antennas are properly aligned, a link will automatically be established. The
front panel LEDs should look like the image below (assuming that DS-3 data
is not yet being sent), indicating that a signal is being transmitted and