Provisioning
42 SkyZhone 45 Installation Guide
DR
A
FT
for reference to software engineers and do not refer to the ODU
software version.
VxWorks OperatingSystem version 5.4
Copyright 2001 Zhone Technologies, Inc.
CPU: SkyZhone45 Indoor Unit IDU
Bootrom version 1.0.1
Created on February 28, 2001 13:41:24
Console Test..................................Passed
Loading the generic system image Please wait...
The image in boot area is good
Generic system image load completed
Generic system image booting. Please wait...
CPU: SkyZhone45 Indoor Unit (IDU)
Generic System Image version 1.0.0.0
SkyZhone45....Beaming your way........
Starting SkyZhone45.
Created on Mar2 2001, 00:09:26
SkyZhone45 Indoor Unit (IDU) is powering on the Outdoor
Unit (ODU), waiting one second...
SkyZhone45 system is ready for operation.
SkyZhone45 is monitoring the line interfaces.
SkyZhone45: Indoor Unit - DS3 Line RX LOS Alarm Set SA
SkyZhone45: Indoor Unit - Radio Link RX OOL Alarm Cleared
NSA
SkyZhone45: Console running...
-ODU->
After the system is initialized, the -ODU-> prompt displays and the system is
ready to be provisioned.
Error Messages
When the ODU receives a command it cannot process, it may not respond, or,
it may return an error message. If there is no response, the command was
entered incorrectly. If either of the sample messages below is returned, the
command was not processed and has to be resent.
>BCC_ _ERR
-ODU->
This message means that part of the command was garbled between the IDU
and the ODU. Repeated messages like this indicate that the communications
link between the IDU and the ODU is not working properly.
>SYN_ _ERR
-ODU->