User's Manual

Table Of Contents
Preparing for Installation
22 SkyZhone 45 Installation Guide
DR
A
FT
Equipment
Before you begin the SkyZhone 45 system installation, make sure that you
have all of the hardware and tools required.
Hardware included with SkyZhone 45 system
The SkyZhone 45 system includes the following hardware:
Two Indoor Units (IDU), each with:
AC power cord
One set 19 in rack mount brackets with screws
One set 23 in rack mount brackets
One surge suppressor for the ODU-IDU cable
This manual in CD ROM format
One Outdoor Unit (ODU) A variant
One Outdoor Unit (ODU) B variant
Two sets of ODU mounting hardware
Two antenna cables, 6 ft LMR-600 with connectors.
Two antennas (2 ft, 4 ft or 6 ft in diameter), each with:
Mounting hardware (design will vary with antenna size)
Installation instructions (will vary with antenna size)
Customer-supplied hardware
The customer is responsible for supplying the following hardware:
Two 19- or 23-inch mounting racks or cabinets for the IDUs. They must
be indoors or in cabinets or vaults protected from moisture.
Mounting structures for the antennas and ODU equipment. They must be
structurally and mechanically adequate for the antenna size and location.
DC power fuse panels, if DC power is used. The DC power must be
supplied from a switched, protected DC power panel.
Ground connections. Grounding connections must be provided at both
IDU and ODU locations.
Installation contractor-supplied hardware
The installation contractor supplies the following hardware:
IDU-ODU interconnecting cables with connectors.