zNID 24xx Series
32 zNID Hardware Installation Guide
GE, FE or CU
Figure 8: zNID-GE-24xx (A and non A), zNID-FE-24xx, zNID-CU-24xx LEDS
Table 4: zNID-GE-24xx (A and non A), zNID-FE-24xx, zNID-CU-24xx LEDs
LED Name Color Indicates
STATUS Green: Heartbeat
(1 short blink every
5 seconds)
Normal Operation
Green: Rapid blink
(10/sec)
Unit has been reset to Factory
Defaults / is unconfigured
Green: Alternating
fast blinking and
Off (1 second rapid
blink/1 second off)
EZ Touch communications in process
Green: Slow blink
(1/second)
Remote Mgt Access (SNMP, HTTP,
Telnet, or TR-069)
Green: On Reboot or restart in process
Off Power off
BATT Yellow: On Operating on Battery Power
Yellow: Slow blink
(1/sec)
Battery Alarm (Low Battery, Missing,
or Replace)
Off Normal operation on AC power
ALARM Red: On Running on battery
Red: 50% cycle: 1
sec Rapid Blink/
1 sec Off
EZ Touch actions pending -- SW or
Config update required
Off Normal operation on AC power
WAN Green: On Link is up and is ready to pass data
Green: Flashing Attempting to establish a link
Off Not provisioned