User's Manual
zNID 24xxA1 Series
30 zNID 24xxA1 Hardware Installation Guide
zNID 24xxA1 series LEDs
The LEDs vary depending on the model of zNID. See zNID 24xxA1 models
on page 23 for a complete list of zNID models.
Figure 6: zNID-GPON-24xxA1 (A and non A) LEDS
Table 5: zNID-GPON-24xxA1 (A and non A) LEDs
LED Name Color Behavior Indicates
STATUS Green Heartbeat
(1 short blink
every 5
seconds)
Normal Operation
Green Rapid blink
(10/sec)
Unit has been reset to Factory
Defaults / is unconfigured
Green Alternating fast
blinking and
Off (1 second
rapid blink/1
second off)
EZ Touch communications in process
Green Slow blink
(1/second)
Remote Mgt Access (OMCI, SNMP,
HTTP, Telnet, or TR-069)
Green On Reboot or restart in process
None Off Power off
BATT Yellow On Operating on Battery Power
Yellow Slow blink (2/
sec)
Battery Alarm (Low Battery,
Missing, or Replace)
None Off Normal operation on AC power
ALARM Red On Running on battery
Red 50% cycle: 1
sec Rapid
Blink/
1 sec Off
EZ Touch actions pending -- SW or
Config update required
None Off Normal operation on AC power