zNID 24xxA1 Series Hardware Installation Guide For software version 4.
DASAN Zhone Solutions 7195 Oakport Street Oakland, CA 94621 USA 510.777.7000 www.zhone.com info@zhone.com COPYRIGHT C2000-2017 DASAN Zhone Solutions, Inc. and its licensors. All rights reserved. This publication is protected by copyright law.
TABLE OF CONTENTS About This Guide 5 Style and notation conventions..............................................................................5 Typographical conventions.......................................................................................6 Related documentation.............................................................................................7 Acronyms......................................................................................................................
Table of Contents Chapter 2 zNID 24xxA1 Installation.....................................................................................35 Install the zNID ..........................................................................................................35 Installation precautions ...........................................................................................37 Mount the zNID ......................................................................................................
ABOUT THIS GUIDE This guide is intended for use by installation technicians, system administrators, or network administrators. It explains how to install the zNID 24xxA1 series enclosure, electronics and cabling. Style and notation conventions This document uses the following conventions to alert users to information that is instructional, warns of potential damage to system equipment or data, and warns of potential injury or death. Carefully read and follow the instructions included in this document.
About This Guide WARNING! A warning alerts users to conditions or actions that could lead to injury caused by a laser. AVERTISSEMENT ! Un avertissement avertit les utilisateurs au sujet d'états ou d'actions qui pourraient entraîner des blessures causées par un laser. WARNING! This icon warns the user that metal surfaces can become hot to touch. Avoid contact or use caution when touching these surfaces.
Related documentation Related documentation Refer to the following publication for additional information: • zNID Quick Installation Instructions for the zNID you are installing. These instructions are shipped with the zNID, but are also available on the DZS website. • zNID RG Configuration Guide — explains how to use the zNID web interface and describes the system commands and parameters.
About This Guide Table 1: Acronyms and their descriptions (Continued) Acronym Description ONU Optical Network Unit PoE Power over Ethernet PPPoE Point-to-point protocol over Ethernet QoS Quality of service RF Radio Frequency RFoG Radio Frequency over Glass SC adaptor Subscriber connector adaptor SIP Session initiation protocol SNMP Simple network management protocol T1/E1 T1 is Trunk line 1 (or DS 1, digital signal level 1).
Important Safety Instructions Important Safety Instructions Read and follow all warning notices and instructions marked on the product and included in the manual. Veuillez lire et respecter toutes les notices d'avertissement et les instructions indiquées sur le produit et inclues dans le manuel. Laser Safety Instructions DZS equipment and associated optical test sets use laser sources that emit light energy into fiber cables.
About This Guide • Prevent direct exposure to optical fiber ends or optical connector ends where laser signals are directly accessed. Do not handle pieces of optical fiber with fingers. Use tweezers or adhesive tape to lift and discard any loose optical fiber ends. • Wear rubber gloves to clean optical connectors. The gloves prevent direct contact with the isopropyl alcohol and prevent contamination of the ferrules with skin oils.
Important Safety Instructions WARNING! AVERTISSEMENT ! Ne regardez jamais dans une fibre optique active ou une ouverture de connecteur de fibre optique d'un appareil actif ou sous tension. Remarque : Lorsque vous travaillez avec des fibres optiques, prenez ces précautions : • Portez les lunettes de protection lorsque vous installez des fibres optiques. • Lavez-vous les mains après avoir manipulé des fibres optiques.
About This Guide • When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. • Install the zNID in accordance with national and local electric codes in order to meet all applicable requirements. Consult a qualified electrical consultant.
Compliance Compliance FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
About This Guide CE CE compliance cerfications has been obtained for the following equipment: GPON 4 Port WiFi Gateway • ZNID-GPON-2424A1, ZNID-GPON-2424A1-XX, ZNID-GPON-2424A1-NYY, ZNID-GPON-2424A1-XX-NYY; • ZNID-GPON-2426A1, ZNID-GPON-2426A1-XX, ZNID-GPON-2426A1-NYY, ZNID-GPON-242461-XX-NYY; • ZNID-GPON-2408A1, ZNID-GPON-2408A1-XX, ZNID-GPON-2408A1-NYY, ZNID-GPON-2408A1-XX-NYY; • ZNID-GPON-2428A1, ZNID-GPON-2428A1-XX, ZNID-GPON-2428A1-NYY, ZNID-GPON-2428A1-XX-NYY; GE 4 Port WiFi Gateway • ZNID
CE Canada Statement This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
About This Guide FCC - Part 68 This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: 6RTDL01A6768. If requested, this number must be provided to the telephone company. This equipment uses the following USOC jacks: RJ-11, RJ-45, USB Jack, Power Jack. REN (Ringer Equivalent Numbers) Statement Notice: The Ringer Equivalence Number (REN: 0.
REN (Ringer Equivalent Numbers) Statement equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier.
About This Guide EMI Precautions Canada This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.
ZNID 24XXA1 SERIES This chapter describes the 24xxA1 series of zNIDs.
zNID 24xxA1 Series of outdoor Multiple Dwelling Unit (MDU) ONTs. SIP-PLAR signaling is supported for connection via DZS's Voice Gateway to traditional Class 5 TDM switches, while both MGCP and SIP are supported for direct connection to a VoIP Softswitch. This flexibility allows DZS's 42xx, 9xxx and 24xx Series ONTs to work in nearly all Telco networks, with interoperability support for a broad array of Softswitches.
Overview zNID 24xxA1 series components The zNID 24xxA1 series indoor ONTs provide a variety of interfaces for triple play deployments. These indoor units may be mounted to a wall or placed on a desktop.
zNID 24xxA1 Series Figure 2: The zNID 24xxA1 series attaches to a fiber tray base Figure 3: The unit may also be wall mounted, with or without a fiber tray 22 zNID 24xxA1 Hardware Installation Guide
zNID 24xxA1 series features zNID 24xxA1 series features Under ideal circumstances, GPON can reach up to 20 or 30 km, however the practical limit is 12 km (about eight miles). Reach is dependent on the configuration of the optical distribution network (ODN). All 24xxA1 series ONTs are designed for indoor use. The 24xxA1 series of zNIDs share a common SW architecture with the 42xx and 9xxx series of zNIDs, including the same intuitive Web interface and command line interface.
zNID 24xxA1 Series zNID 24xxA1 series specifications The possible interfaces and number of interfaces depend on the specific model, see zNID 24xxA1 models on page 23 for a list of models and their interfaces. Table 3: zNID 24xxA1 common specifications Specifications Values Dimensions ~1.50 in (38 mm) high x 10.00 in (254 mm) wide x 5.98 in (152 mm) deep height does not include feet Weight 500 g (1.1 lb.
zNID 24xxA1 series features Table 3: zNID 24xxA1 common specifications (Continued) Specifications Values Interfaces Uplinks: • • GPON: SC/APC connector for ZNID-GPON-24xxA1 – 1.244Gbps Burst Mode Upstream Transmitter (1310nm) – 2.488Gbps Downstream Receiver (1490nm) – Downstream Video Receiver (1550nm) for ZNID-GPON-2403, 2425, 2427 only GE: SC/UPC connector for ZNID-GE-24xxA1 SFF non-removable optics work over a 20km distance – 1.244Gbps Upstream Transmitter (1310nm) – 1.
zNID 24xxA1 Series Table 3: zNID 24xxA1 common specifications (Continued) Specifications Values Protocol Support • • GPON uplink – ITU-T G.984 (GPON) – Multiple T-CONTS per device – Multiple GEM Ports per device – 1:1 mapping of GEM ports into T-CONTS with priority queue based scheduling – Activation with automatic discovered SN and password in conformance with ITU-T G.984.3 – AES-128 Decryption with key generation and switching – FEC (Forward Error Correction) – 802.
zNID 24xxA1 series features Table 3: zNID 24xxA1 common specifications (Continued) Specifications Values POTS (Voice) Support • SIP (RFC 3261) • • • • SIP-PLAR • • Echo Canceling, Voice Activity Detection (VAD), Comfort Noise Insertion (CNI) • • T.30 and T.
zNID 24xxA1 Series Table 4: ONT Power Requirements Model Watts Voltage Amps Typical ZNID-2428A1 19W 12VDC 2A 15-19W ZNID-2426A1 15W 12VDC 1.5A 13-15W ZNID-2424A1 12W 12VDC 1.5A 12-13W WARNING! Using a power supply not meeting these requirements may result in system damage, overheating, or even fire. ATTENTION! L'utilisation d'une source d'alimentation électrique qui ne répond pas à ces exigences peut résulter dans les dommages du système, une surchauffe, ou même un incendie.
zNID 24xxA1 series dimensions zNID 24xxA1 series dimensions Figure 4: zNID 24xxA1 dimensions Figure 5: zNID fiber tray dimensions zNID 24xxA1 Hardware Installation Guide 29
zNID 24xxA1 Series zNID 24xxA1 series LEDs The LEDs vary depending on the model of zNID. See zNID 24xxA1 models on page 23 for a complete list of zNID models.
zNID 24xxA1 series LEDs Table 5: zNID-GPON-24xxA1 (A and non A) LEDs LED Name Color Behavior Indicates WAN Green On Ranged successfully Green Slow blink (1/sec) Ranging in progress None Off Not ready for ranging or not provisioned Green On OMCI provisioning is complete Green Rapid blink (10/sec) OMCI provisioning is written to FLASH Green Slow blink (1/second) OMCI provisioning is in progress None Off No OMCI provisioning Green On Internet service is available None Off Intern
zNID 24xxA1 Series Table 5: zNID-GPON-24xxA1 (A and non A) LEDs 32 LED Name Color Behavior Indicates 5.8 Green On 5.8GHz WiFi service is enabled on ONT Green Slow blink (1/second) 5.8GHz WiFi data passing between ONT and connected device None Off 5.
Logging in to the 24xxA1 series zNID Logging in to the 24xxA1 series zNID The zNID 24xxA1 series may be managed from OMCI, Web UI or CLI. This section describes logging into the zNID locally using the subscriber facing LAN port, GE1. Figure 7: Log into GE port 1 to reach the Web UI or CLI on the zNID To login with a browser: 1 Connect an Ethernet cable from your computer to GE1 on the zNID. 2 Launch a browser and point it to 192.168.1.1. 3 Enter the username and password.
zNID 24xxA1 Series 34 zNID 24xxA1 Hardware Installation Guide
ZNID 24XXA1 INSTALLATION This chapter can be used as separate installation instructions. This chapter explains how to install the zNID 24xxA1 hardware. It includes the following sections: • Install the zNID, page 35 • Overview of zNID 24xxA1 series installation, page 36 Install the zNID This section describes the procedures for installing the zNID. The overiew procedure provides options for wall mounting or placing the zNID on a surface with or without the optional fiber tray.
zNID 24xxA1 Installation Overview of zNID 24xxA1 series installation 1 Select the location Ensure that the environment is free of dust and excessive moisture and has sufficient ventilation. The zNID may be installed in a vertical or horizontal orientation (wall or desktop.
Installation precautions Installation precautions Maximum operating temperature should not exceed the range of 0° C to 40° C (32° F to 104° F). Ensure that proper cable grades are used for all system and network connections. For best results, use the cables and connectors recommended in this document. Connect the system to the power supply circuit as described in this document. Before making fiber connections, be sure that the optical cable fiber tips and components are clean and free of dust and debris.
zNID 24xxA1 Installation Mount the zNID The zNID enclosure can be mounted on a vertical surface or a horizontal surface (wall or desktop). • Wall mount with fiber tray on page 38 • Wall mount without fiber tray on page 41 • Desktop with fiber tray on page 43 Wall mount with fiber tray The zNID fiber tray can be mounted on a wall using four screws. Caution: To prevent damage to the enclosure, use screws appropriate to the mounting surface.
Installation precautions Mounting the zNID fiber tray on a wall To mount the zNID fiber tray on a wall: Figure 8: Installing the fiber tray on a wall 1 Prepare the surface for mounting.
zNID 24xxA1 Installation 2 Hold the bracket level in the desired location and mark the hole positions. The holes for the fiber tray are 8 cm apart (about 3.15 inches or a little less than 3 and 3/16 inches) on the horizontal axis and 4 cm apart (about 1.57 inches or about 1 and 9/16 inches) on the vertical axis. 3 Drill the holes. 4 Line up the fiber tray with the screw holes and attach the screws. Use attaching hardware appropriate for the type of surface to which the unit is mounted (i.e.
Installation precautions Wall mount without fiber tray Caution: To prevent damage to the enclosure, use screws appropriate to the mounting surface. Précaution : Afin d'éviter d'endommager l'enceinte, utilisez des vis adaptées à la surface de montage. Caution: Install the zNID fiber tray a proper height from the floor. Précaution : Installez le plateau de fibres zNID à une hauteur correcte par rapport au sol. Caution: The zNID should always be mounted in a vertical orientation.
zNID 24xxA1 Installation Mounting the zNID on a wall without the fiber tray Figure 9: Installing the fiber tray on a wall To mount the zNID directly on a wall: 1 42 Prepare the surface for mounting.
Installation precautions 2 Mark the hole positions. The holes for the fiber tray are 13 cm apart (about 5.12 inches or a little less than 5 and 1/8 inches) on the horizontal axis. 3 Drill the holes. 4 Attach the screws. Use screws appropriate for the type of surface to which the unit is mounted (i.e. wood, brick, CB, etc.). 5 Put the zNID on the screws. The screws should be leave enough space from being flush with the wall for the zNID legs to hold the unit firmly against the wall.
zNID 24xxA1 Installation Manage the optical cable When making a fiber optic connection, avoid touching the fiber cable ends to the outside of the mating connector. Touching can contaminate the connectors. Fiber handling Before making any connections, be sure that the optical cable fiber tips and components are clean and free of dust and debris. The zNID fiber tray provides fiber spools and hooks to avoid sharp bends in the fiber cable.
Installation precautions Optical fiber cable placement in the zNID fiber tray Using a fiber tray involves routing the optical fiber around the spools, then physically to the SC connector in the zNID. Note: Sharp bends in fiber cables create undesirable optical attenuation or loss. The zNID enclosure provides fiber spools and hooks to avoid sharp bends in the fiber cable. A minimum bend radius of 30 mm (1.2 in) is recommended for stripped fiber.
zNID 24xxA1 Installation Connect to network Connecting the SC connectors on fiber based models Connect the SC connector from the electronics module to the SC connector in the zNID enclosure. Observe the necessary precautions to decrease the risk of exposure to laser radiation. WARNING! Risk of eye damage. At all times when handling optical fibers, follow the safety procedures recommended by your company. AVERTISSEMENT ! Risque de blessure aux yeux.
Connect to network Figure 12: zNID-GE-24xxA1 model uses SC/UPC connector (blue) 2 Remove the dust covers from the SC optical connectors. Clean the connector if necessary. 3 Plug in the fiber connector to connect the zNID to the network. Note: To function properly the optical strength to the zNID should be between -8dBm and -27dBm for GPON and between -2dBm and -23dBm for GE units. See Testing optical power on page 44 for information.
zNID 24xxA1 Installation Connect power The zNID is powered by 12VDC using the DC Power Supply which is shipped with the unit. An optional uninterruptable power supply may also be used. Figure 13: The zNID 24xxA1 has both a DC power connector and a UPS input for power Note: The DC power connector and UPS input must not be used at the same time. For pinout information for the UPS connector, see UPS pinouts on page 56.
Connect to network Connecting phone terminals The zNID 24xxA1 models have the ability to connect POTS via RJ-11. Connecting POTS The zNID 24xxA1 models have the ability to connect POTS via RJ-11 connector. The terminal connections are shown in Figure 14. 1 Locate the subscriber’s telephone wire pair. Figure 14: Connect phone lines 2 If the wire pair is not terminated, follow local practices to attach an RJ-11 connector.
zNID 24xxA1 Installation Connecting Ethernet ports The zNID-24xxA1 series models have up to 4 Gigabit Ethernet ports. Connect Ethernet ports The zNID provides RJ eight pin modular jacks (RJ45) for Ethernet connections. Ethernet connections can be used to deliver any packet services including IPTV, data, and VoIP. For Ethernet services, connect a Category 5 or a Category 6 cable to an RJ45 interface as shown in Figure 15. 1 Locate the Ethernet LAN cable.
Connect to network Connecting USB port The zNID-24xxA1 series models have a USB 2.0 port for future applications. Figure 16: The USB port.
zNID 24xxA1 Installation Complete the zNID installation After making the physical connections, complete the installation by checking the LEDs, the grounding for the full enclosure, closing the outer cover, sealing the entry holes, and screwing in the final screw to secure the unit. Checking the LEDs Check the LEDs to verify that power is working. See the zNID 24xxA1 series LEDs on page 30.
APPENDIX: PINOUTS This appendix provides the following pinouts • Gigabit Ethernet pinouts on page 54 • POTS pinouts on page 55 • UPS pinouts on page 56 zNID 24xxA1 Hardware Installation Guide 53
Appendix: Pinouts Gigabit Ethernet pinouts Figure 17: The Gigabit Ethernet ports use an RJ45 connector Table 8: Pinout for the GigE RJ45 54 Pin Name Description 1 TX_D1+ Transceive data + 2 TX_D1- Transceive data - 3 RX_D2+ Recieve data + 4 BI_D3+ Bi-directional data + 5 BI_D3- Bi-directional data - 6 RX_D2- Receive data - 7 BI_D4+ Bi-directional data + 8 BI_D4- Bi-directional data - zNID 24xxA1 Hardware Installation Guide
POTS pinouts POTS pinouts Figure 18: The POTS ports use an RJ11 connector Table 9: Pinout for the POTS RJ11 Pin Description 1 N/C 2 N/C 3 Ring 4 Tip 5 N/C 6 N/C zNID 24xxA1 Hardware Installation Guide 55
Appendix: Pinouts UPS pinouts Figure 19: Pin out layout for the UPS connector Table 10: Pinout descriptions for the UPS connection 56 Pin Signal Comments 1 +12V UPS in 2 GND UPS return.
INDEX B M buttons 21 Manage the optical cable 44 C O Checking LEDs 52 Connect power 48 Connect to network 46 Connecting Ethernet ports 50 Connecting phone terminals 49 Connecting POTS 49 Connecting USB port 51 Operating 24 Operating temperature 24 Overview 19 D Desktop with fiber tray 43 Dimensions 24 displays 21 P Pinout GigE RJ45 54 POTS RJ11 55 UPS connection 56 Pinouts 53 POTS pinouts 55 Power 24 power 48 E R Ethernet connection 50 F Fiber handling 44 fiber tray base 22 G Gigabit Ethernet pi
Index W wall mount 38 Wall mount with fiber tray 38 Wall mount without fiber tray 41 Weight 24 Z zNID Ethernet connection 50 interfaces 25 LEDs 52 power 48 voice support 27 58 zNID 24xxA1 Hardware Installation Guide wall mount 38 zNID 24xxA1 Installation 35 zNID 24xxA1 models 23 zNID 24xxA1 Series 19 zNID 24xxA1 series components 21 zNID 24xxA1 series features 23 zNID 24xxA1 series specifications 24 ZNID-GE-2408A1 23 ZNID-GE-2424A1 23 ZNID-GE-2426A1 23 ZNID-GE-2428A1 23 ZNID-GPON-2408A1 23 ZNID-GPON-24