Installation manual
30
5
5
5
0
120
0
0
AC Failure Report Delay (0 -255 min)
Siren Time (1 - 255 min)
Twin Trip Time (0 - 255 min)
Chime Option (‘0’ = Follow, ‘5’ = Chime once, ‘255’ = Latch)
Dialer Delay Time (0 - 255 sec)
Fire Alarm Verification Time (120 – 255 sec)
Reserved
Zone Inactivity Time (days) (see Feature 22, Segment 6, Option 3 to change to hours)
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
2
Dynamic Battery Test Duration (0 – 255 min)
Segment 3
On if code pad sounds for ‘Telephone Line Cut ‘ when the system is armed
On if code pad sounds during Twin Trip time
On if code pad sounds when a Low Battery is detected
On if code pad sounds for Expander Trouble
On if code pad sounds for ‘Telephone Line Cut‘ when disarmed
On if code pad sounds for Zone and Box Tampers
On if code pad sounds upon AC Power Failure
On if code pad sounds for Medical Alarm
Pg
35
Code Pad Sounder Control
24
Feat.
Segment 1
3
4
7
8
5
1
2
6
20
0
Partial Arm Entry Time (10 - 255 sec)
Strobe Time (0 - 255 hours)
Segment 1
Segment 2
Pg
35
System Timers
25
Feat.
0
Reserved
Segment 12
0
Reserved
Segment 13
0
Reserved
Segment 14
Pg
37
Pg
37
Auxiliary Output 1 - Event & Time
Auxiliary Output 2 - Event & Time
28
Feat.
29
Feat.
51
7
0
0
53
53
0
0
Event A for Aux Out 1
(Default Event 51 = Strobe)
Event A for Aux Out 2
(Default Event 7 = Any Siren)
Event B for Aux Out 1
(Default Event 53 = False)
Event B for Aux Out 2
(Default Event 53 = False)
Logic for Aux Out 1
(Default Logic0=OR)
Logic for Aux Out 2
(Default Logic0=OR)
Timing for Aux Out 1
(Default Timing0=Follow)
Timing for Aux Out 2
(Default Timing 0 = Follow)
Segment 1
Segment 1
Segment 3
Segment 3
Segment 2
Segment 2
Segment 4
Segment 4
Pg
36
Pg
37
Auxiliary Output 1-4 Area Selection
Auxiliary Outputs 1-4 Special Timing
26
Feat.
27
Feat.
On if output should be timed in minutes; Off if timed in seconds
Area 1
Segment 1
(Aux Out 1)
Segment 1
(Aux Out 1)
Segment 2
(Aux Out 2)
Segment 2
(Aux Out 2)
Segment 3
(Aux Out 3)
Segment 3
(Aux Out 3)
Segment 4
(Aux Out 4)
Segment 4
(Aux Out 4)
On if output should latch; Off if output should be timed
Area 2
On if output should stop timing upon code entry; Off if output to follow timer
Area 3
On if output to only activate between the closing and opening time (F33, F34)
Area 4
On if output to only activate between the opening and closing time (F33, F44)
Area 5
On if output inverted (0 volts going to 12 volts when activated)
Area 6
Reserved
Area 7
Reserved
Area 8
1 1 1 1
2 2 2 2
4 4 4 4
6 6 6 6
7 7 7 7
8 8 8 8
5 5 5 5
3 3 3 3
3 3 3 3
7 7 7 7
1 1 1 1
2 2 2 2
4 4 4 4
6 6 6 6
8 8 8 8
5 5 5 5