Installation manual
Pg
32
Zone 9-16 Area Selection
21
Feat.
Pg
31
Zone 9-16 Configuration Groups
20
Feat.
16 16
Area 1
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4
6 6 6 6 6 6 6 6
7 7 7 7 7 7 7 7
8 8 8 8 8 8 8 8
1 1 1 1 1 1 1 1
5 5 5 5 5 5 5 5
Segment 1
(Zone 9)
Segment 2
(Zone 10)
Segment 3
(Zone 11)
Segment 4
(Zone 12)
Segment 5
(Zone 13)
Segment 6
(Zone 14)
Segment 7
(Zone 15)
Segment 8
(Zone 16)
16 16 16 16 16 16
Pg
31
Zone 1-8 Area Selection
19
Feat.
Area 1
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4
6 6 6 6 6 6 6 6
7 7 7 7 7 7 7 7
8 8 8 8 8 8 8 8
1 1 1 1 1 1 1 1
5 5 5 5 5 5 5 5
Segment 1
(Zone 1)
Segment 2
(Zone 2)
Segment 3
(Zone 3)
Segment 4
(Zone 4)
Segment 5
(Zone 5)
Segment 6
(Zone 6)
Segment 7
(Zone 7)
Segment 8
(Zone 8)
Pg
29
Area 1 - Entry / Exit Timers
17
Feat.
30
30
60
60
Entry Timer #1
Entry Timer #2
Exit Timer #1
Exit Timer #2
Segment 1
Segment 3
Segment 2
Segment 4
Pg
29
Zone 1-8 Configuration Groups
18
Feat.
7 1616161616163
Reserved Reserved
Segment 5 Segment 6
Pg
35
Siren / Communicator Attempt Count
Feat.
23
0
On if Box Tamper report enabled
On enable Lost Clock service light
On if Fail To Communicate report enabled
Enable Two Wire Smoke
On if Siren Supervision report enabled
On will prevent force armed zones to report bypass
On if End Download report enabled
Reserved
On if Auxilary Power Over-current report enabled
On will enable all Dual End of Line (DEOL) resistors on all zones
On if Start/End programming report enabled
Reserved
On if Expander Trouble reporting enabled
On will Auto Partial Arm Area 1
On if Expander Module (number) to be reported via the Contact I.D
Reserved
On if AC Fail reporting enabled
On enables Zone Doubling
On if Log Full report enabled
Reserved
On if Telephone Line Cut report enabled
On enables Silent Exit option
On if Sensor Low Battery report enabled
Disable Clean-Me Reports (not used in Australia)
On if Low Battery reporting enabled
On disables all hardwired zones on the NX board
On if Auto-test report enabled
Enable Zone Inactivity Time In Hours
Reserved
Reserved
On if Sensor Missing report enabled
Disable Steady (Temporal) Siren (On enables Evacuation Siren for fire
Segment 3
Segment 5
Segment 4
Segment 6
1
2 2
3 3
4 4
6 6
7
7 7
8 8
5 5
3 3
1 1
2
4 4
6 6
5 5
8
1
On if siren sounds for ‘Telephone Line Cut’ when armed On to enable Voltage Output; Off to enable On-board Siren Driver
On if siren blast at closing kiss-off On if Battery Missing Test is performed every 12 seconds
On if siren blast at exit delay expiration On if First to Open Last to Close Reports
Siren blasts 1x for key-switch / wireless arming; 2x for disarming On if Box Tamper Pins on the control panel are enabled
On if siren sounds for ‘Telephone Line Cut’ when disarmed On if sirens should sound on expander trouble
On if siren limited to once per zone On if Strobe flashes for 3s for Key-switch Arm and 6s for Disarm
On if siren blast at arming On if Communicator limited to once per zone
On if siren sounds for a Zone or Box Tamper On if Manual Communicator Test performed during [*]-[44] function
Pg
32
System Options
22
Feat.
Segment 1 Segment 2
1
2 2
3 3
4 4
7 7
5 5
1
6 6
8 8
7
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Segment 7
1
2
3
4
6
7
8
5
2