Installation manual

© Hills Industries 2009 Page 58
NX-408E / NX-416E / NX-448E Wireless Receiver Address Settings
Module
Number
Reported
Switch 1 Switch 2 Switch 3 Switch 4
1
st
32 ON OFF ON OFF
2
nd
33 OFF ON ON OFF
3
rd
34 ON ON ON OFF
4
th
35 OFF OFF OFF OFF
5
th
36 ON OFF OFF OFF
6
th
37 OFF ON OFF OFF
7
th
38 ON ON OFF OFF
8
th
39 OFF OFF ON OFF
NX-507E / NX-508E Relay / Output Expanders
Module
Number
Reported
Switch 1 Switch 2 Switch 3 Switch 4
1
st
24 ON ON OFF
2
nd
25 OFF OFF ON
3
rd
26 ON OFF ON
4
th
27 OFF ON ON
5
th
28 ON ON ON
6
th
29 OFF OFF OFF
7
th
30 ON OFF OFF
8
th
31 OFF ON OFF
When
set to
OFF
disables
tamper
feature
Max no. of
NX-507E / NX-508E
modules supported
Reliance 8 = 3
Reliance 12\128 = 8
NX-320 Remote Power Supply
Module
Number
Reported
Switch 1 Switch 2 Switch 3
1
st
84 OFF OFF OFF
2
nd
85 ON OFF OFF
3
rd
86 OFF ON OFF
4
th
87 ON ON OFF
5
th
88 OFF OFF ON
6
th
89 ON OFF ON
7
th
90 OFF ON ON
8
th
91 ON ON ON
Recommendation
It is highly advised to disconnect all power (incl backup battery) from the panel before connecting new expander modules,
on power up the control panel will enrol modules. Next enter program mode and default the new module:
[] 8 [Program Code] [Module Number] # 9 1 0 # [Exit] [Exit] [Wait 10 seconds] the module is now ready to be
used/programmed.