Installation manual

© Hills Industries 2009 Page 56
Appendix 2: Reporting Fixed Codes in Contact I.D.
The table below lists the CID event codes sent for the following reports (if enabled). The number in brackets following the
event is the number that will be reported as the zone number if extended Contact I.D. is enabled in the system options.
Otherwise zone ‘0’ will always be reported. If there are no parentheses, the zone will be reported as ‘0’.
Report
Contact I.D.
Event
Manual Test
Auto test Open (user number)
Close (user number)
Cancel (user number)
Download Complete
Start Program
End Program
Ground Fault
Ground Fault Restore
Recent Close (user number)
Exit Error (user number)
Event Log Full
Fail To Communicate
Expander Trouble
Expander Restore
Telephone Fault
Telephone Restore
Siren Tamper
Siren Restore
Aux Power Over Current
Aux Power Restore
Low Battery
Low Battery Restore
AC Fail
AC Restore
Box Tamper
Box Tamper Restore
Code Pad Tamper
Code Pad Panic
Duress
Code Pad Fire
Code Pad Medical
RF Sensor Lost (zone number)
RF Sensor Restore (zone number)
Sensor Low Battery (zone number)
Sensor Battery Restore (zone number)
Zone Trouble (zone number)
Zone Trouble Restore (zone number)
Zone Tamper (zone number)
Zone Tamper Restore (zone number)
Zone Bypass (zone number)
Bypass Restore (zone number)
Zone Inactivity
Late To Close
Forced Door
601
602
401
406
412
627
628
310
310
401
457
605
354
333
333
351
351
321
321
312
312
309
309
301
301
137
137
137
120
121
110
100
381
381
384
384
380
380
137
137
570
570
391
new
454 new
423 new