Installation manual

© Hills Industries 2009 Page 47
Feature 69 Configuration Group 2 Alarm Event Code
Segment 1 3
Feature 69 contains the Contact I.D. event code sent for zone configuration group 2 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.
Feature 70 new Configuration Group 2 Characteristic Select
Seg 1 5 Seg 2 2457 Seg 3 25678 Seg 4 new Seg 5 new
Use ‘Configuration Group Characteristic table’ described in Feature 68, of this section.
Feature 71
Configuration Group 3 Alarm Event Code
Segment 1 3
Feature 71 contains the Contact I.D. event code sent for zone configuration group 3 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.
Feature 72 new Configuration Group 3 Characteristic Select
Seg 1 5 Seg 2 24578 Seg 3 25678 Seg 4 new Seg 5 new
Use ‘Configuration Group Characteristic table’ described in Feature 68, of this section.
Feature 73 Configuration Group 4 Alarm Event Code
Segment 1 3
Feature 73 contains the Contact I.D. event code sent for zone configuration group 4 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.
Feature 74 new Configuration Group 4 Characteristic Select
Seg 1 6 Seg 2 2578 Seg 3 25678 Seg 4 new Seg 5 new
Use ‘Configuration Group Characteristic table’ described in Feature 68, of this section.
Feature 75 Configuration Group 5 Alarm Event Code
Segment 1 3
Feature 75 contains the Contact I.D. event code sent for zone configuration group 5 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.
Feature 76 new Configuration Group 5 Characteristic Select
Seg 1 6 Seg 2 24578 Seg 3 25678 Seg 4 new Seg 5 new
Use ‘Configuration Group Characteristic table’ described in Feature 68, of this section.
Feature 77 Configuration Group 6 Alarm Event Code
Segment 1 3
Feature 77 contains the Contact I.D. event code sent for zone configuration group 6 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.